Plated Floor Underfloor Heating Systems
Suitable for application where suspended timber floors are to be installed, without raising the floor level. To accommodate this, aluminium heat conduction panels are fitted between the joists and nailed or stapled in place. With joists centres of 400mm, a plate 388mm* wide is used, having two channels along its length, on 200mm centres (*other sizes are available to order). Underfloor pipe is run in the plate channels in a snake pattern, with the pipe turning between the joists at one end and a through notch cut into the joist at the other. |
 |
|
The aluminium heat conduction panels should be fitted to standard joist centres on 400mm. 100mm insulation must be fitted below the plates. Once all the underfloor heating pipe work is fitted, this is again pressure-tested with water or air to ensure any damage resulting in a leak will be immediately obvious. |
|
|
 |
|